Heatmiser UH8-RF V2 8 Zone Wireless Wiring Centre
The Heatmiser UH8-RF V2 8 Zone Wireless Wiring Centre is a professional-grade control hub for underfloor heating systems. It provides tidy, centralised connections for actuators, boiler enable, and pump control, while receiving wireless signals from compatible Heatmiser thermostats. If you want clean wiring, reliable zone control, and easy expansion, UH8-RF V2 is the go-to choice.
What the UH8-RF V2 Does
UH8-RF V2 simplifies installation by bringing all UFH zone wiring to one location. It manages up to 8 heating zones using thermal actuators and offers dedicated outputs for boiler and pump. Because it’s the RF (wireless) version, it pairs with Heatmiser’s wireless thermostats for a cable-free room control setup — perfect for retrofits, extensions, and projects where chasing cables isn’t practical.
- Controls up to 8 UFH heating zones via thermal actuators
- Dedicated boiler enable and pump outputs
- Wireless pairing with compatible Heatmiser thermostats
- Clean, centralised wiring and easy fault-finding
- Expandable system architecture for future zones
Perfect with Heatmiser Wireless Thermostats
Pair the wiring centre with the Neoair V3 Wireless Smart Thermostat for flexible, battery-powered room control without chasing cables. Add a Heatmiser NeoHub for app control, multi-zone scheduling, and smart integrations. Together, they deliver a powerful, modern UFH control ecosystem that scales as your project grows.
Key Features
- 8 Zones: Each zone output drives thermal actuators for precise room-by-room control.
- Boiler & Pump: Built-in relay outputs coordinate heat calls efficiently.
- Wireless Control: Receives RF signals from compatible Heatmiser thermostats.
- Neat Installation: Central hub keeps wiring organised and accessible.
- Failsafe Operation: Clear terminal layout for fast commissioning and service.
Installation & Commissioning
Mount the wiring centre near the manifold to minimise actuator cable runs and keep the installation tidy. Connect actuators to zone outputs, then wire the boiler enable and pump outputs. Pair your wireless thermostats following Heatmiser’s on-board instructions. With the Heatmiser UH8-RF V2 8 Zone Wireless Wiring Centre, installers gain quick diagnostics and homeowners gain smooth, reliable comfort control.
- Install adjacent to the manifold for shortest actuator runs
- Label zones clearly for streamlined commissioning
- Pair wireless thermostats room-by-room
- Optionally add NeoHub for app control and scheduling
Compatibility
- Wireless thermostats: Neoair series (e.g. Neoair V3)
- Smart control: Works with Heatmiser NeoHub and Heatmiser Neo app
- Systems: Hydronic (wet) underfloor heating with thermal actuators
- Ancillaries: UFH manifolds, actuators, boiler, and pump
Core Specifications
- Model: Heatmiser UH8-RF V2
- Zones: 8 heating zones (actuator outputs)
- Outputs: Boiler enable relay, pump relay
- Communication: RF pairing with compatible wireless thermostats
- Use Case: New builds, extensions, and retrofits where wireless room control is preferred
Why Heatmiser
Heatmiser is a trusted UK manufacturer known for robust hardware, clear software, and dependable support across residential and commercial projects. Learn more at the official site: heatmiser.com.
Summary
For a neat, reliable, and scalable UFH installation, the Heatmiser UH8-RF V2 8 Zone Wireless Wiring Centre delivers. Combine it with Neoair V3 and NeoHub to create a modern, multi-zone wireless control system that’s simple to commission and effortless to live with.
One-time purchase:
£148.85 (inc VAT)
Fast UK delivery. Free Delivery on orders over £50.
In stock

New Blending Valve with Wilo A RATED pump 8m assembled - ZL-2536B-W8
New Blending Valve with Bastion A rated 6 meter pump - ZL-2536B-B6
Non-mixing pump set with Grundfos UPM3 Flex assembled - ZL-2536C-GF
Blending Valve with Wilo A RATED pump 8m assembled - ZL-2536W-W8
Wilo pump cable - ACC-WCABLE
Blending Valve with Bastion A rated 7.5 meter pump - ZL-2536RP-7.5
ZL-2548V with Bastion A Rated 6 meter Assembled - ZL-2548RP-6
Blending Valve with Grundfos UPM3 Flex assembled - ZL-2536W-GF
Blending Valve with Wilo A RATED pump 6m assembled - ZL-2536W-W6
ES Single Room System with Wilo A RATED pump 6m - ZL-2532B-W6
ES Single Room System with Grundfos UPM3 Auto Pump - ZL-2532B-GA
Blending valve with thermostat head - ZL-2548V
Wilo A rated Pump 8 metre head inc cable - WILO05
UFH 22mm Heatguard - ZL-2138
New Blending Valve with Bastion A rated 7.5 meter pump - ZL-2536B-B7.5
New Blending Valve with Wilo A RATED pump 6m assembled - ZL-2536B-W6
Single Room System with Wilo A RATED pump 6m - ZL-2532W-W6
New Blending Valve with Grundfos UPM3 Auto assembled - ZL-2536B-GA
Grundfos UPM3 AUTO Pump 25-70 130 - GP-UPM3-AUTO-25/70
ES Single Room Mixture Pump Pack - ZL-2532B
Grundfos UPM3 Flex Pump 25-70 130 - GP-UPM3-FLEX-25/70
Single Room System with Grundfos Flex Pump - ZL-2532W-GF
Single Room System with Wilo A RATED pump 8m - ZL-2532W-W8
ES Single Room System with Grundfos UPM3 Flex Pump - ZL-2532B-GF
Heatmiser NeoHub
ES Single Room System with Wilo A RATED pump 8m - ZL-2532B-W8
ES Single Room System with Bastion A RATED pump 6m - ZL-2532B-B6
Wilo A rated Pump 6 metre head inc cable - WILO01
Single Room System with Grundfos Auto Pump - ZL-2532W-GA
7 Ways 1" Brass Nickel-plated manifold with red handle - ZL-1121RR07
Single Room System with Bastion A RATED pump 6m - ZL-2532W-B6
8 Ways 1" Brass Nickel-plated manifold with red handle - ZL-1121RR08
6 Ways 1" Brass Nickel-plated manifold with red handle - ZL-1121RR06
10 Ways 1" Brass Nickel-plated manifold with red handle - ZL-1121RR10
Heatmiser UH8-RF V2 8 Zone Wireless Wiring Centre
Neoair V3 Wireless Smart Thermostat
Power Adapter - ZL-DZ-1001
Single Room Mixture Pump Pack - ZL-2532W
9 Ways 1" Brass Nickel-plated manifold with red handle - ZL-1121RR09 